Main Page | Report this Page
 
   
Science Forum Index  »  Electronics - Equipment Forum  »  wavetek 9100...Looking for some help. is there anybody...
Page 1 of 1    
Author Message
izmirli...
Posted: Fri Jun 06, 2008 1:57 am
Guest
hi to everybody.
it is first time, i am writing something to the elsmar forum...i hope
to find some solution for my problem about my wavetek 9100.

it fails in self-test:

results of FULL TEST...: 2 fails.
_____________
1. Test Number: S03.002

Meas.Value =+12.180057
Upper Lim.Value =+5.875000
Lower Lim.Value=+0.625000
Measured A = +12.180964
Measured B =+12.179151
Description: HF sine VCO control range Lo via V tune.
____________
2. Test Number: S04.003

Meas.Value= - 4.211193
Upper Lim.Value = - 0.150000
Lower Lim.Value = - 2.250000
Measured A = - 4.211193
Measured B = - 4.211193
DEscription: Control volts pin diode max via TT401



______________
Looking for some help. is there anybody who knows something about
it?????

Thanks..
See u
 
Page 1 of 1       All times are GMT - 5 Hours