On Feb 27, 6:21 pm, JW <n...@dev.null> wrote:
On Tue, 26 Feb 2008 12:43:15 -0800 (PST) free_electron
ultravin...@gmail.com> wrote in Message id:
aeb976ad-d087-4607-9885-60b61c225...@q78g2000hsh.googlegroups.com>:
Anyone knows what the error means ? i know its in the extended service
errors. Unfortunately the docs in Hp website say its explained on page
10.1 and their doc ends at 9.8 ....
i had a hardcopy of the manual somwhere but can;t find it right now ..
drat !
Would be cool if i can fix it. ( i've fixed 3 or 4 of these before. )
Hello free_electron,
I've fixed a few of these myself - it's a well laid out unit and easy to
work on. Does this help?:
Shaper Output State
Test E51
The shaper IC U401 is not able to supply positive output when -90"
startphase and complement output mode are selected with triangle
waveform (VCO not triggered).Possible faults:
VCO (Slope) IC Al: U201
Waveform switching Al: U104
Reference voltage switching Al: U204
Amplitude DAC A2: U27, U28, U17
Refer to Chapter 10.5, Chapter 10.3 and Chapter 10.4.