Posted: Sat Mar 29, 2008 1:29 am |
|
|
|
Guest
|
I'm picking up the radiator for the SA 200 Monday, and will be painting and
reassembling according to the wind speed over the next couple of weeks.
When I get the old gal running, I'd like to do a check on the output through
the leads.
Would I do this with a helper and an amp clamp? Set it up to weld, and then
weld with a helper watching an amp clamp on the lead? Is there another type
of tester I should use just on the main lugs off the machine? I'm just
trying to see if the output is good, and is within the range of the controls
indicate. I will be using 50' leads of #1 cable on each leg. I will be
using 7018 1/8" rod in the flat position, and making a dime size pool, and
trying to burn thirty seconds per setting. Stinger positive.
Does this sound like a plausible idea? Other suggestions, caveats, tips,
procedures or whatever appreciated.
Thanks.
Steve |
|
|
| Back to top |
|
| Jim Wilkins |
Posted: Sat Mar 29, 2008 2:00 am |
|
|
|
Guest
|
On Mar 29, 2:29 am, "SteveB" <oldf...@flatulence.com> wrote:
Quote: ..., I'd like to do a check on the output through
the leads.
Would I do this with a helper and an amp clamp? Set it up to weld, and then
weld with a helper watching an amp clamp on the lead? Is there another type
of tester I should use just on the main lugs off the machine? I'm just
trying to see if the output is good, and is within the range of the controls
indicate. I will be using 50' leads of #1 cable on each leg. I will be
using 7018 1/8" rod in the flat position, and making a dime size pool, and
trying to burn thirty seconds per setting. Stinger positive.
Does this sound like a plausible idea? Other suggestions, caveats, tips,
procedures or whatever appreciated.
Thanks.
Steve
You could use an automotive starting/charging current meter, which is
a simple DC magnetic meter with grooves on the back for the wire. They
aren't very accurate but you just place it on the lead. The one I have
reads charging current to 75A with 5A graduations, or 400A starting
current to 25A.
6013 or 7014 rod (and maybe 7018, haven't tried it) will weld by
itself if laid flat on the work, then you could let go and read the
meter.
I'd be more concerned with maximum AC line current.
Jim Wilkins |
|
|
| Back to top |
|
| Grant Erwin |
Posted: Sat Mar 29, 2008 2:28 am |
|
|
|
Guest
|
SteveB wrote:
Quote: I'm picking up the radiator for the SA 200 Monday, and will be painting and
reassembling according to the wind speed over the next couple of weeks.
When I get the old gal running, I'd like to do a check on the output through
the leads.
Would I do this with a helper and an amp clamp? Set it up to weld, and then
weld with a helper watching an amp clamp on the lead? Is there another type
of tester I should use just on the main lugs off the machine? I'm just
trying to see if the output is good, and is within the range of the controls
indicate. I will be using 50' leads of #1 cable on each leg. I will be
using 7018 1/8" rod in the flat position, and making a dime size pool, and
trying to burn thirty seconds per setting. Stinger positive.
Does this sound like a plausible idea? Other suggestions, caveats, tips,
procedures or whatever appreciated.
Thanks.
Steve
You need a clamp-on DC ammeter, else sure, have someone read the current.
Grant |
|
|
| Back to top |
|
| Gunner |
Posted: Sat Mar 29, 2008 5:34 am |
|
|
|
Guest
|
On Sat, 29 Mar 2008 00:29:57 -0600, "SteveB" <oldfart@flatulence.com>
wrote:
Quote: I'm picking up the radiator for the SA 200 Monday, and will be painting and
reassembling according to the wind speed over the next couple of weeks.
When I get the old gal running, I'd like to do a check on the output through
the leads.
Would I do this with a helper and an amp clamp? Set it up to weld, and then
weld with a helper watching an amp clamp on the lead? Is there another type
of tester I should use just on the main lugs off the machine? I'm just
trying to see if the output is good, and is within the range of the controls
indicate. I will be using 50' leads of #1 cable on each leg. I will be
using 7018 1/8" rod in the flat position, and making a dime size pool, and
trying to burn thirty seconds per setting. Stinger positive.
Does this sound like a plausible idea? Other suggestions, caveats, tips,
procedures or whatever appreciated.
Thanks.
Steve
Unless you have a DC amp clamp..you cant do it. Most ammeters using
inductince to read current, are AC only. Your machine is DC only.
Put a volt meter across the leads, see what it says. Have your helper
read it while welding.
Frankly..I consider the dials on most welders to be only a a way to
figure out what the needle was pointing at the last time it worked
good. Then I use a grease pencil to make a mark for the size/type of
rod it worked well at.
Now there is "shunt ammeters" but I dont have a clue how to hook one
up for your rig.
Just wire wheel some of your scrap, grab a mixture of rod, and burn
it. Set it at what the dial says..then adjust up or down as needed for
each rod.
Gunner |
|
|
| Back to top |
|
| Jim Wilkins |
Posted: Sat Mar 29, 2008 6:09 am |
|
|
|
Guest
|
On Mar 29, 10:54 am, "SteveB" <oldf...@flatulence.com> wrote:
Quote: "Jim Wilkins" <KB1...@gmail.com> wrote in message
news:947692e0-f873-4d5b-90a1-cca3eee7a8c6@c65g2000hsa.googlegroups.com...
On Mar 29, 2:29 am, "SteveB" <oldf...@flatulence.com> wrote:
..., I'd like to do a check on the output through
the leads.
Would I do this with a helper and an amp clamp? Set it up to weld, and
then
weld with a helper watching an amp clamp on the lead? Is there another
type
of tester I should use just on the main lugs off the machine? I'm just
trying to see if the output is good, and is within the range of the
controls
indicate. I will be using 50' leads of #1 cable on each leg. I will be
using 7018 1/8" rod in the flat position, and making a dime size pool, and
trying to burn thirty seconds per setting. Stinger positive.
Does this sound like a plausible idea? Other suggestions, caveats, tips,
procedures or whatever appreciated.
Thanks.
Steve
You could use an automotive starting/charging current meter, which is
a simple DC magnetic meter with grooves on the back for the wire. They
^^^^^^^
aren't very accurate but you just place it on the lead. The one I have
reads charging current to 75A with 5A graduations, or 400A starting
current to 25A.
6013 or 7014 rod (and maybe 7018, haven't tried it) will weld by
itself if laid flat on the work, then you could let go and read the
meter.
I'd be more concerned with maximum AC line current.
Jim Wilkins
This machine is DC only.
So is car starter current.
If it welds OK with the largest appropriate rod, it's working
properly.
Jim Wilkins |
|
|
| Back to top |
|
| Bob Engelhardt |
Posted: Sat Mar 29, 2008 6:52 am |
|
|
|
Guest
|
Gunner wrote:
Quote: Unless you have a DC amp clamp..you cant do it. Most ammeters using
inductince to read current, are AC only. ...
My Fluke does DC amps. Has a "Max" mode too, where it remembers the max
current - you wouldn't need a helper to read the meter while you're welding.
Bob |
|
|
| Back to top |
|
| Pete C. |
Posted: Sat Mar 29, 2008 8:18 am |
|
|
|
Guest
|
Bob Engelhardt wrote:
Quote:
Gunner wrote:
Unless you have a DC amp clamp..you cant do it. Most ammeters using
inductince to read current, are AC only. ...
My Fluke does DC amps. Has a "Max" mode too, where it remembers the max
current - you wouldn't need a helper to read the meter while you're welding.
Bob
I found a rather nice hall effect AC/DC clamp probe by TPI at FRy's for
about $60 (plug into any DMM), and it's rated for 1,600A AC / 2,000A DC.
A whole lot cheaper than the Fluke equivalent and seems to work just
fine. |
|
|
| Back to top |
|
| Pilgrim |
Posted: Sat Mar 29, 2008 9:43 am |
|
|
|
Guest
|
You could use a shunt type meter. The most common meter standard for
these are 50 millivolts. You will need a meter movement and a shunt
covering the maximum current you will be reading. The shunt should be
placed in series with either welder lead observing the polarity from the
welder, shunt and meter movement. This will be the most accurate, but a
clamp on attachment to a DVM, as others have suggested, should be quite
adequate.
Chuck P. |
|
|
| Back to top |
|
| Ignoramus10476 |
Posted: Sat Mar 29, 2008 9:48 am |
|
|
|
Guest
|
I would use a DC shunt, as you said, and a regular multimeter set at
the lowest voltage scale (2000 mV in my case).
These shunts are not very expensive.
If you know the gauge and exact length of your cables, you can short
your welder through those cables and measure voltage drop, and arrive
at a fairly good current number based on resistance of cable of your
gauge.
i
On 2008-03-29, Pilgrim <pilgrim@noemail.net> wrote:
Quote: You could use a shunt type meter. The most common meter standard for
these are 50 millivolts. You will need a meter movement and a shunt
covering the maximum current you will be reading. The shunt should be
placed in series with either welder lead observing the polarity from the
welder, shunt and meter movement. This will be the most accurate, but a
clamp on attachment to a DVM, as others have suggested, should be quite
adequate.
Chuck P. |
|
|
| Back to top |
|
| SteveB |
Posted: Sat Mar 29, 2008 9:54 am |
|
|
|
Guest
|
"Jim Wilkins" <KB1DAL@gmail.com> wrote in message
news:947692e0-f873-4d5b-90a1-cca3eee7a8c6@c65g2000hsa.googlegroups.com...
On Mar 29, 2:29 am, "SteveB" <oldf...@flatulence.com> wrote:
Quote: ..., I'd like to do a check on the output through
the leads.
Would I do this with a helper and an amp clamp? Set it up to weld, and
then
weld with a helper watching an amp clamp on the lead? Is there another
type
of tester I should use just on the main lugs off the machine? I'm just
trying to see if the output is good, and is within the range of the
controls
indicate. I will be using 50' leads of #1 cable on each leg. I will be
using 7018 1/8" rod in the flat position, and making a dime size pool, and
trying to burn thirty seconds per setting. Stinger positive.
Does this sound like a plausible idea? Other suggestions, caveats, tips,
procedures or whatever appreciated.
Thanks.
Steve
You could use an automotive starting/charging current meter, which is
a simple DC magnetic meter with grooves on the back for the wire. They
aren't very accurate but you just place it on the lead. The one I have
reads charging current to 75A with 5A graduations, or 400A starting
current to 25A.
6013 or 7014 rod (and maybe 7018, haven't tried it) will weld by
itself if laid flat on the work, then you could let go and read the
meter.
I'd be more concerned with maximum AC line current.
Jim Wilkins
This machine is DC only.
Steve |
|
|
| Back to top |
|
| Tom M |
Posted: Sat Mar 29, 2008 10:39 am |
|
|
|
Guest
|
"Ignoramus10476" <ignoramus10476@NOSPAM.10476.invalid> wrote in message
news:e9udnbCQc4wgy3PanZ2dnUVZ_oPinZ2d@giganews.com...
Quote:
If you know the gauge and exact length of your cables, you can short
your welder through those cables and measure voltage drop, and arrive
at a fairly good current number based on resistance of cable of your
gauge.
This is really good advise. I would get an analog voltmeter and measure the
voltage drop just across the work lead. Measure the length, look up the
resistance of that size cable and calculate the current. Note the temp of
the cable and correct for that for more accuracy.
Easy, cheap, and accurate. |
|
|
| Back to top |
|
| Gunner |
Posted: Sat Mar 29, 2008 10:55 am |
|
|
|
Guest
|
On Sat, 29 Mar 2008 08:18:49 -0500, "Pete C." <aux3.DOH.4@snet.net>
wrote:
Quote:
Bob Engelhardt wrote:
Gunner wrote:
Unless you have a DC amp clamp..you cant do it. Most ammeters using
inductince to read current, are AC only. ...
My Fluke does DC amps. Has a "Max" mode too, where it remembers the max
current - you wouldn't need a helper to read the meter while you're welding.
Bob
I found a rather nice hall effect AC/DC clamp probe by TPI at FRy's for
about $60 (plug into any DMM), and it's rated for 1,600A AC / 2,000A DC.
A whole lot cheaper than the Fluke equivalent and seems to work just
fine.
Really? Fry's Electronics
Big box store to the nerds?
Ill check there myself. Id like to have one.
Gunner |
|
|
| Back to top |
|
| Ignoramus10476 |
Posted: Sat Mar 29, 2008 11:55 am |
|
|
|
Guest
|
On 2008-03-29, Tom M <tmiller@umaryland.edu> wrote:
Quote:
"Ignoramus10476" <ignoramus10476@NOSPAM.10476.invalid> wrote in message
news:e9udnbCQc4wgy3PanZ2dnUVZ_oPinZ2d@giganews.com...
If you know the gauge and exact length of your cables, you can short
your welder through those cables and measure voltage drop, and arrive
at a fairly good current number based on resistance of cable of your
gauge.
This is really good advise. I would get an analog voltmeter and measure the
voltage drop just across the work lead. Measure the length, look up the
resistance of that size cable and calculate the current. Note the temp of
the cable and correct for that for more accuracy.
Easy, cheap, and accurate.
That's a good idea. Voltage drop may be about 1 v olt, easily
measurable with good accuracy. There are ohms per foot tables for
various gauges. Attaching one
i
AWG Wire Table for BARE COPPER Wire Compiled by a program written by Fr. Tom McGahee
Compiled by Fr. Tom McGahee tom_mcgahee@sigmais.com
Permission granted to copy freely so long as credit line above is included
AWG = American Wire Gauge size
Dia-mils = Diameter in mils (1 mil = .001 inch)
TPI = Turns Per Inch (Ignoring thickness of unknown insulation)
Dia-mm = Diameter in millimeters (For comparison with non-USA coilers)
Circ-mils = Circular Mils. (circular mils = diameter in mils squared)
Ohms/Kft = Ohms Per 1,000 Feet
Ft/Ohm = Feet Per Ohm
Ft/Lb = Feet Per Pound
Ohms/Lb = Ohms Per Pound
Lb/Kft = Pounds Per 1,000 Feet
NormAmps = Normal Average Amp Capacity based on 500 circular mils per Amp
MaxAmps = Maximum recommended Average Amp Capacity in Open Air based on 438.489 circular mils per Amp
Actual Amp capacity of a wire depends on form factor and method of cooling!
MaxAmps assumes free flow of air around wire. Do NOT exceed this maximum without cooling!
Wire wrapped in a coil or without any form of cooling may over-heat at MaxAmps!
Many factors govern the ACTUAL Max Amps you can pass through a wire continuously. Be careful!
AWG Dia-mils TPI Dia-mm Circ-mils Ohms/Kft Ft/Ohm Ft/Lb Ohms/Lb Lb/Kft NormAmps MaxAmps
0000 459.99 2.1740 11.684 211592 0.0490 20402 1.5613 0.0001 640.48 423.18 482.55
000 409.63 2.4412 10.405 167800 0.0618 16180 1.9688 0.0001 507.93 335.60 382.68
00 364.79 2.7413 9.2657 133072 0.0779 12831 2.4826 0.0002 402.80 266.14 303.48
AWG Dia-mils TPI Dia-mm Circ-mils Ohms/Kft Ft/Ohm Ft/Lb Ohms/Lb Lb/Kft NormAmps MaxAmps
0 324.85 3.0783 8.2513 105531 0.0983 10175 3.1305 0.0003 319.44 211.06 240.67
1 289.29 3.4567 7.3480 83690 0.1239 8069.5 3.9475 0.0005 253.33 167.38 190.86
2 257.62 3.8817 6.5436 66369 0.1563 6399.4 4.9777 0.0008 200.90 132.74 151.36
3 229.42 4.3588 5.8272 52633 0.1970 5075.0 6.2767 0.0012 159.32 105.27 120.03
4 204.30 4.8947 5.1893 41740 0.2485 4024.7 7.9148 0.0020 126.35 83.480 95.190
5 181.94 5.4964 4.6212 33101 0.3133 3191.7 9.9804 0.0031 100.20 66.203 75.489
6 162.02 6.1721 4.1153 26251 0.3951 2531.1 12.585 0.0050 79.460 52.501 59.866
7 144.28 6.9308 3.6648 20818 0.4982 2007.3 15.869 0.0079 63.014 41.635 47.476
8 128.49 7.7828 3.2636 16509 0.6282 1591.8 20.011 0.0126 49.973 33.018 37.650
9 114.42 8.7396 2.9063 13092 0.7921 1262.4 25.233 0.0200 39.630 26.185 29.858
AWG Dia-mils TPI Dia-mm Circ-mils Ohms/Kft Ft/Ohm Ft/Lb Ohms/Lb Lb/Kft NormAmps MaxAmps
10 101.90 9.8140 2.5881 10383 0.9989 1001.1 31.819 0.0318 31.428 20.765 23.678
11 90.741 11.020 2.3048 8233.9 1.2596 793.93 40.122 0.0505 24.924 16.468 18.778
12 80.807 12.375 2.0525 6529.8 1.5883 629.61 50.593 0.0804 19.765 13.060 14.892
13 71.961 13.896 1.8278 5178.3 2.0028 499.31 63.797 0.1278 15.675 10.357 11.810
14 64.083 15.605 1.6277 4106.6 2.5255 395.97 80.447 0.2031 12.431 8.2132 9.3654
15 57.067 17.523 1.4495 3256.7 3.1845 314.02 101.44 0.3230 9.8579 6.5134 7.4271
16 50.820 19.677 1.2908 2582.7 4.0156 249.03 127.91 0.5136 7.8177 5.1654 5.8900
17 45.257 22.096 1.1495 2048.2 5.0636 197.49 161.30 0.8167 6.1997 4.0963 4.6709
18 40.302 24.813 1.0237 1624.3 6.3851 156.62 203.39 1.2986 4.9166 3.2485 3.7042
19 35.890 27.863 0.9116 1288.1 8.0514 124.20 256.47 2.0648 3.8991 2.5762 2.9376
AWG Dia-mils TPI Dia-mm Circ-mils Ohms/Kft Ft/Ohm Ft/Lb Ohms/Lb Lb/Kft NormAmps MaxAmps
20 31.961 31.288 0.8118 1021.5 10.153 98.496 323.41 3.2832 3.0921 2.0430 2.3296
21 28.462 35.134 0.7229 810.10 12.802 78.111 407.81 5.2205 2.4521 1.6202 1.8475
22 25.346 39.453 0.6438 642.44 16.143 61.945 514.23 8.3009 1.9446 1.2849 1.4651
23 22.572 44.304 0.5733 509.48 20.356 49.125 648.44 13.199 1.5422 1.0190 1.1619
24 20.101 49.750 0.5106 404.03 25.669 38.958 817.66 20.987 1.2230 0.8081 0.9214
25 17.900 55.866 0.4547 320.41 32.368 30.895 1031.1 33.371 0.9699 0.6408 0.7307
26 15.940 62.733 0.4049 254.10 40.815 24.501 1300.1 53.061 0.7692 0.5082 0.5795
27 14.195 70.445 0.3606 201.51 51.467 19.430 1639.4 84.371 0.6100 0.4030 0.4596
28 12.641 79.105 0.3211 159.80 64.898 15.409 2067.3 134.15 0.4837 0.3196 0.3644
29 11.257 88.830 0.2859 126.73 81.835 12.220 2606.8 213.31 0.3836 0.2535 0.2890
AWG Dia-mils TPI Dia-mm Circ-mils Ohms/Kft Ft/Ohm Ft/Lb Ohms/Lb Lb/Kft NormAmps MaxAmps
30 10.025 99.750 0.2546 100.50 103.19 9.6906 3287.1 339.18 0.3042 0.2010 0.2292
31 8.9276 112.01 0.2268 79.702 130.12 7.6850 4145.0 539.32 0.2413 0.1594 0.1818
32 7.9503 125.78 0.2019 63.207 164.08 6.0945 5226.7 857.55 0.1913 0.1264 0.1441
33 7.0799 141.24 0.1798 50.125 206.90 4.8332 6590.8 1363.6 0.1517 0.1003 0.1143
34 6.3048 158.61 0.1601 39.751 260.90 3.8329 8310.8 2168.1 0.1203 0.0795 0.0907
35 5.6146 178.11 0.1426 31.524 328.99 3.0396 10480 3447.5 0.0954 0.0630 0.0719
36 5.0000 200.00 0.1270 25.000 414.85 2.4105 13215 5481.7 0.0757 0.0500 0.0570
37 4.4526 224.59 0.1131 19.826 523.11 1.9116 16663 8716.2 0.0600 0.0397 0.0452
38 3.9652 252.20 0.1007 15.723 659.63 1.5160 21012 13859 0.0476 0.0314 0.0359
39 3.5311 283.20 0.0897 12.469 831.78 1.2022 26496 22037 0.0377 0.0249 0.0284
AWG Dia-mils TPI Dia-mm Circ-mils Ohms/Kft Ft/Ohm Ft/Lb Ohms/Lb Lb/Kft NormAmps MaxAmps
40 3.1445 318.01 0.0799 9.8880 1048.9 0.9534 33410 35040 0.0299 0.0198 0.0226
Prev: DIY Ball Lightning
Next: Medhurts K formula [Qbasic listing]
Index(es):
Main
Thread |
|
|
| Back to top |
|
| Pete C. |
Posted: Sat Mar 29, 2008 12:36 pm |
|
|
|
Guest
|
Gunner wrote:
Quote:
On Sat, 29 Mar 2008 08:18:49 -0500, "Pete C." <aux3.DOH.4@snet.net
wrote:
Bob Engelhardt wrote:
Gunner wrote:
Unless you have a DC amp clamp..you cant do it. Most ammeters using
inductince to read current, are AC only. ...
My Fluke does DC amps. Has a "Max" mode too, where it remembers the max
current - you wouldn't need a helper to read the meter while you're welding.
Bob
I found a rather nice hall effect AC/DC clamp probe by TPI at FRy's for
about $60 (plug into any DMM), and it's rated for 1,600A AC / 2,000A DC.
A whole lot cheaper than the Fluke equivalent and seems to work just
fine.
Really? Fry's Electronics
Big box store to the nerds?
Yep. Bright yellow case unit. They have a couple models that look
superficially the same, two are AC only and the third is AC/DC and has
the extra DC zero knob on it. It also apparently was rated something
like 800A, but subsequently upgraded with stickers on the package to the
1,600A AC / 2,000A DC rating. |
|
|
| Back to top |
|
| Ernie Leimkuhler |
Posted: Sat Mar 29, 2008 12:57 pm |
|
|
|
Guest
|
In article <GllHj.1136$yD6.441@newsfe08.phx>,
"SteveB" <oldfart@flatulence.com> wrote:
Quote: I'm picking up the radiator for the SA 200 Monday, and will be painting and
reassembling according to the wind speed over the next couple of weeks.
When I get the old gal running, I'd like to do a check on the output through
the leads.
Would I do this with a helper and an amp clamp? Set it up to weld, and then
weld with a helper watching an amp clamp on the lead? Is there another type
of tester I should use just on the main lugs off the machine? I'm just
trying to see if the output is good, and is within the range of the controls
indicate. I will be using 50' leads of #1 cable on each leg. I will be
using 7018 1/8" rod in the flat position, and making a dime size pool, and
trying to burn thirty seconds per setting. Stinger positive.
Does this sound like a plausible idea? Other suggestions, caveats, tips,
procedures or whatever appreciated.
Thanks.
Steve
I have an Extech Ammeter that reads AC and DC amps.
It cost me $85 at Fry's Electronics.
It works great, and is fairly compact. |
|
|